A 22 uH drum-core inductor reads 22.3 uH on the bench at zero bias. Push 12 A through the same part and it measures 8.9 uH.
Nothing in the copper changed between those two readings. What changed is the magnetic field inside the core, and how much of that field the ferrite could still support at 12 A. The gap between the datasheet inductance and the in-circuit inductance is where most inductor designs run into trouble, and it is almost always a field problem rather than a winding problem.
The field is the storage medium. Inductance is only the bookkeeping number that describes how much flux the winding links per ampere at one operating point.
What the magnetic field in an inductor actually is
The magnetic field in an inductor is the field created by current flowing through the winding, shaped and concentrated by the core along a defined path. Every turn produces a small field ring around its wire; stack enough turns on a shared path and those rings merge into one larger field that crosses the core and returns through the surrounding space.
Three quantities describe that field, and mixing them up is the most common source of design error:
- Field strength H, in amperes per metre, set only by ampere-turns and the length of the magnetic path.
- Flux density B, in tesla, equal to H multiplied by the permeability of the material the path runs through.
- Flux, in webers, equal to B multiplied by the cross-sectional area the field crosses.
H = N x I / le. Permeability never changes H. It changes how much B you get for that H, and therefore how much flux, inductance and stored energy the same winding produces.
That distinction matters in practice because it tells you which lever to pull. Changing the winding changes H. Changing the core changes what H turns into.
From field strength to inductance
Inductance is flux linkage per ampere, so the field only counts through the flux it links: L = N x flux / I. Substitute flux = B x Ae and B = permeability x H, and the familiar scaling appears.
L rises with permeability, with turns squared and with core area, and falls with magnetic path length.
Two consequences decide most real designs:
- Turns enter squared. Doubling turns on the same core quadruples inductance and halves the current at which the core reaches saturation, so a rewind is never a neutral change.
- Path length sits in the denominator. Lengthening the magnetic path, which an air gap does, lowers inductance and raises the current the part can carry before the field saturates.
Datasheet AL values are measured at tiny flux levels, usually a few millitesla. They describe the small-signal field, not the field at full load, and treating the two as interchangeable is how a 22 uH part becomes a 9 uH part in the first prototype.
The energy the field actually holds is 0.5 x L x I squared. That number, not the inductance, sets core size in a boost converter or a flyback transformer.
Why the core material dominates the field
The core material sets both how strongly the field is multiplied and the point at which multiplication stops, which is why material choice outranks winding detail in most designs.
2000 to 2500Initial permeability of typical power MnZn grades
400 to 500 mTSaturation flux density at 25 degrees C, falling with heat
0.1 to 10 ohm-mResistivity of MnZn ferrite, orders above copper
The same construction rule explains why a core swap changes so much at once:
How core construction changes the field a winding can support before saturation.
| Core construction |
Effective permeability |
Field behaviour |
Typical use |
| Air or non-magnetic |
About 1 |
No saturation, very low flux |
Radio-frequency chokes, low-value filtering |
| Ungapped MnZn power ferrite |
2000 to 2500 |
High flux from low current, knee arrives early |
Output chokes with modest DC bias |
| Gapped MnZn power ferrite |
100 to 400 |
Lower flux per ampere, wider bias range |
PFC chokes, flyback and forward transformers |
Yaorun specifies its Mn-Zn power ferrite grades on exactly these axes, with permeability, saturation and loss quoted per grade rather than as one headline number.
MnZn Ferrite Core ManufacturersManganese-zinc ferrite power type material is a material that can produce large magnetic induction strength and energy conversion efficiency at a certain frequency. It...View Product →
A grade with 2500 permeability and a grade with 1200 permeability can share the same footprint and the same saturation limit. The difference is how much field the winding produces for a given current, not how much the core can hold.
Where the field hits its limits
The field inside an inductor stops rising in proportion to current once the core approaches saturation, and temperature moves that ceiling down.
- Saturation. As flux density approaches the material limit, permeability collapses and incremental inductance falls toward that of an air coil. The part still works; it simply stops behaving like an inductor.
- DC bias. A standing direct current consumes flux headroom, so the alternating swing has less room before the knee.
- Temperature. MnZn saturation flux density falls as the core heats, so a part that looks comfortable at 25 degrees C can be marginal at 100 degrees C.
Ungapped core
- Maximum inductance per turn
- Large flux from a small current
- Reaches the knee with modest DC bias
- Best for signal and filter windings
Gapped core
- Lower effective permeability
- Holds more energy before saturation
- Flatter inductance across the current range
- Fringing flux at the gap can heat windings
A gap does not weaken a core; it moves the energy storage out of the ferrite and into the field in the gap. That is the mechanism that lets a gapped core hold more joules before it saturates.
How frequency changes what the field does
At higher frequency the same flux swing repeats more often per second, so loss per unit volume rises and eddy currents inside the ferrite stop being a footnote.
- Core loss. Loss per unit volume scales with frequency raised to a material exponent and flux density raised to another, so doubling frequency at a fixed swing more than doubles the heat.
- Eddy currents. Ferrite resistivity, several orders of magnitude above copper, is what keeps circulating currents small enough to ignore; it is also why ferrite displaced laminated steel above roughly 20 kHz.
- Skin effect in the winding. At 100 kHz the copper skin depth is about 0.21 mm, so conductors thicker than roughly 0.4 mm carry most of their current near the surface and the remaining copper mostly adds loss.
- Permeability roll-off. Above the useful band of the material, permeability falls, the field spreads, and inductance drops before saturation is anywhere near.
A core running at 20 kHz with 100 mT of swing can overheat at 200 kHz with the same 100 mT, because the field does the same work ten times more often.
Grade selection at this point becomes a loss question rather than an inductance question; the practical mechanics are covered in this note on how MnZn ferrite reduces core losses.
Where the stored field does useful work
Four functions account for most inductor field design in power electronics.
- Energy transfer. In a buck or boost converter the field recharges every switching cycle, and its collapse is what pushes energy to the output.
- Energy storage. In a PFC choke the field must hold the full line-current energy without saturating at the peak of the mains cycle.
- Interference suppression. In a common-mode choke, the field from differential current cancels while the field from common-mode current adds, blocking noise without loading the signal.
- Coupling. In a transformer the field deliberately links a second winding, and the design question becomes coupling coefficient and leakage rather than storage.
Transformer and Inductor Series for Multiple ApplicationsThis category lists transformer and inductor series for TV, communications, lighting, and new energy, relevant to inductor design and production validation.View Product →
Every one of those functions depends on the same property: a field that can be built and collapsed repeatably at the switching rate, without saturating and without overheating.
Checks worth running before you commit to a core
Five checks separate a design that survives production from one that fails on the first thermal soak.
- Field at peak current. Compute H = N x I / le, then convert to B using the material permeability at your hottest operating temperature rather than at 25 degrees C.
- Bias derating. Read the inductance against current curve for the grade, not the AL value from the summary table.
- Saturation margin. Keep peak flux density below roughly 80 percent of the saturation limit at the hottest expected operating point.
- Loss budget. Add core loss at the actual swing and frequency to copper loss, then compare the total against what the thermal path can remove.
- Tolerance stack-up. Gapped cores commonly carry AL tolerances from 3 percent to 25 percent; check what the worst case does to ripple current and peak flux.
A design that passes all five on paper still needs the assembled part measured at full load and at temperature, because the field does not follow the datasheet once the core is hot.
Where derating data for a candidate grade is incomplete, request inductance against current and loss against flux density at temperature before tooling is cut. The Yaorun material team can share those curves for the YR series as part of grade selection.
Questions engineers ask about inductor fields
Does the magnetic field in an inductor depend on the core?
Yes, in two different ways. Field strength H depends only on ampere-turns and path length, so the winding sets it. Flux density B and inductance both depend on the core, because permeability multiplies H. Remove an ungapped MnZn core and inductance falls by roughly the ratio of the two permeabilities.
Where is the field strongest inside an inductor?
Along the core path, and at the gap in a gapped core, where flux fringes outward into the surrounding space. That fringing field can couple into adjacent turns and cause local heating in copper placed too close to the gap.
What happens to the field when the current stops?
It collapses, and the changing flux linkage induces a voltage that opposes the change in current, v = L x di/dt. In a switching converter that induced voltage is the mechanism transferring stored energy to the output.
Can the field from one inductor disturb its neighbours?
Yes. Leakage flux that leaves the core couples into nearby loops. Shielded and pot-core constructions contain it better than open drum cores, and rotating two unshielded chokes by 90 degrees reduces coupling noticeably.
Rule of thumb: if an inductor's measured inductance at full load is below about 70 percent of its no-load value, the field is already close to the saturation knee and there is little margin left for temperature.